Datasheet

RUW15 Series
Isolated Ultra-Wide Input DC/DC Converters
KDC_RUW15.B02 Page 1 of 13
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
SELECTION GUIDE
Order Code
1
Input Voltage
Output
Voltage
Output Current Output Power
MTTF
3
Min. Max. Max.
Nom. V A A W
kHrs
RUW15SL05C SL 5 0.3 3 15 1609
RUW15SL05HC SL 5 0.3 3 15 1218
RUW15SL12C
SL 12 0.125 1.25 15 1550
RUW15SL12HC
SL 12 0.125 1.25 15 959
RUW15SL24C SL 24 0.0625 0.625 15 1094
RUW15SL24HC SL 24 0.0625 0.625 15 1176
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
2
Continuous operation SL I/P types 16 160 V
Input standby current 5.5 mA
INPUT CURRENT (10% Load)
Order Code
Input Voltage Units
16 24 48 60 72 96 110 132 160 V
RUW15SL05C 0.130 0.085 0.040 0.030 0.020 0.013
A
RUW15SL05HC 0.138 0.087 0.042 0.028 0.019 0.014
RUW15SL12C
0.135 0.088 0.044 0.035 0.030 0.023 0.022 0.018 0.015
RUW15SL12HC 0.146 0.093 0.048 0.038 0.032 0.025 0.024 0.021 0.018
RUW15SL24C 0.160 0.102 0.053 0.043 0.036 0.029 0.028 0.025 0.021
RUW15SL24HC 0.146 0.098 0.049 0.039 0.033 0.027
0.025 0.022 0.018
INPUT REFLECTED RIPPLE
Order Code
Input Voltage Units
16 24 48 72 110 160 V
RUW15SL05C 422 327 236 203 174 154
mAp-p
RUW15SL05HC 482 273 175 135 144 106
RUW15SL12C
332.8 309.2 184.8 155.2 138.8 119.6
RUW15SL12HC 292.4 236.8 142.4 107 86.5 76.3
RUW15SL24C 406.4 387.6 249.6 195.6 167.5 138.8
RUW15SL24HC 446.4 291.2 176.4 157.2 101.8 82.7
EFFICIENCY
Order Code
Input Voltage Units
24 48 72 110 160
V
Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ.
RUW15SL05C 74.4 75.9 74.3 75.8 73 74.9 71.3 73.7 64.2 69
%
RUW15SL05HC 71.1 72.2 72.8 73.8 72.1 73.3 70.6 72.3 61.5 66.7
RUW15SL12C
75.1 77.3 75.7 77.8 73.4 76.6 71.8 75.4 64.7 70
RUW15SL12HC 70.6 73.5 73.1 75.7 71.8 75 70.4 73.9 62.1 68.1
RUW15SL24C 74.5 78.4 74.8 78.8 73.9 77.9 72.1 75.9 64.4 70
RUW15SL24HC 71 74.9 72.9 76.9 72.2 76.2 69.9 74.2 62.9 67.8
1. Part numbers ending HC include optional Power Fail /DC OK signal and circuitry to facilitate long hold up time.
2. Will operate down to 14V for 100ms as required by EN 50155 (24V system).
3. Using Telecordia Issue 1 method I case 1 operating temperature 25C
All specifications typical at TA=25°C and rated output current unless otherwise s
FEATURES
nUL 60950 recognised for reinforced
insulation
nHigh transient voltage withstand capability
nUltra wide input voltage range of
16-160VDC
nExternally settable hold up time with
additional capacitor
nDC OK/Power Fail signal
nShort circuit protection
nOver Temperature protection
nOver voltage protection
DESCRIPTION
The RUW series is particularly suitable for use
in applications in railway, industry or telecom-
munication where variable input voltages or
high transient voltages are present. With an ultra
wide input voltage range of 16-160VDC, the
RUW series is capable of withstanding surges
from 24,36,48,72, 90 and 110V systems, largely
eliminating the requirement for input protection
circuitry.
Optional features include a Power Fail/DC OK
signal and circuitry to facilitate long hold-up times
with a small external capacitor across ±Vint pins.

Summary of content (13 pages)