Datasheet

RBE-12/20-D48 Series
Eighth-Brick 240-Watt Isolated DC/DC Converters
MDC_RBE-12-20-D48.B05Δ Page 8 of 16
www.murata-ps.com/support
TYPICAL PERFORMANCE DATA
Effi ciency vs. Line Voltage and Load Current @ 25°C
70
75
80
85
90
95
100
0 5 10 15 20 25
Load Curre nt (Amps)
V
IN
= 36V
V
IN
= 48V
V
IN
= 75V
Efficiency (%)
Thermal image with hot spot at full load current with 30°C ambient; air is fl owing at 100
LFM. Air is fl owing across the converter from -Vin to +Vin at 48V input.
Identifi able and recommended maximum value to be verifi ed in application.
Typical Output Voltage (Vout) vs. Input Voltage (Vin) at +25°C
The RBE-12/20-D48 is not designed to be operated within the shaded area.
The output voltage will be fully regulated within the white area in the graph
above. Operation outside of this area is not recommended for normal use.
Typical Output Voltage (Vout) Vs. Output load at +25°C
10.4
10.6
10.8
11
11.2
11.4
11.6
11.8
12
1 2 3 4 5 6 7 8 9 1011121314151617181920
Output Voltage/Vout
Load/A
36V
48V
75V
10.6
10.8
11.2
11.4
11.6
11.8
12.2
11
12
Output Voltage/Vout
Input Voltage/Vin
10A
20A
no load