Datasheet

PAH-28 Vout, 350-Watt Series
Isolated, 350-Watt, Half-Brick DC-DC Converters
MDC_PAH-28Vout-350W.B05 Page 1 of 21
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
For applications requiring improved electrical and
thermal performance, consider Murata’s new PAH
series “Half Brick” DC-DC power converters. These
compact modules measure 2.3" X 2.4" X 0.5" (58
X 61 X 12.7mm) and offer the industry-standard
Half Brick footprint.
The PAH Series is ideal for power amplifi er
applications, wireless networks, and telecom
applications. The baseplate provides a means for
conduction cooling in demanding thermal environ-
ment conditions.
The module provides a 28Vdc output at 12.5 Amps
and accepts a wide input voltage range of 18-36 or
36-75 Vdc. The PAH topology offers high effi ciency
(up to 93%), tight line and load regulation, low ripple/
noise, and a fast dynamic load response. A single-
board, highly optimized thermal design contributes to
the superior thermal performance.
These half-bricks provide output trim, sense
pins, and primary side on/off control. Standard fea-
tures also include input under-voltage shutdown,
output over-voltage protection, output short-circuit/
current limiting protection, and thermal shutdown.
PRODUCT OVERVIEW
Typical unit
Typical topology is shown. Some models may vary slightly.
FEATURES
28Vout @ 12.5A (350W)
Trimmable 16.8 Vout to 32.2 Vout @ 350W
with Vin = 18-36V (D24) or 36-75V (D48)
Industry Standard “Half Brick” package
High Effi ciency: up to 93%
Outstanding thermal performance
Standard baseplate for conduction cooled
applications
No output reverse conduction
Input to Output Isolation, 2250Vdc (Basic)
Input under-voltage lockout
On/Off Control (Positive or Negative Logic)
Output over-voltage protection
Thermal shutdown
Output short circuit protection (hiccup
technique)
Certifi ed to UL/EN 60950-1, CSA-C22.2 No.
60950-1, 2nd edition safety approvals
Figure 1. Simplifi ed Schematic
Typical unit
F1
External
DC
Power
Source
Reference and
Error Amplifier
-Vout
Cout
+Vout
Trim
On/Off
Control
-Vin
Open = On
+Vin
logic)
Controller
and Power
Barrier
Case ground
NOTE: A minimum of 470µF
of capacitance is required
on the output to ensure
stable operation. An ESR
equal to or less than 0.02
is also required.
Output (V) Current (A) Input Voltage (V)
28 12.5 18-36 or 36-75

Summary of content (21 pages)