Datasheet
Output Capacitive Load
These converters do not require external capacitance added to achieve
rated specifi cations. Users should only consider adding capacitance to reduce
switching noise and/or to handle spike current load steps. Install only enough
capacitance to achieve noise objectives. Excess external capacitance may
cause regulation problems, degraded transient response and possible oscilla-
tion or instability.
The maximum rated output capacitance and ESR specifi cation is given for a
capacitor installed immediately adjacent to the converter. Any extended output
wiring or smaller wire gauge or less ground plane may tolerate somewhat
higher capacitance. Also, capacitors with higher ESR may have a larger capaci-
tance. What counts here is the instantaneous maximum output current during
power-on charge-up and switching currents under load. Excessive current will
trip the overcurrent detection and shut off the converter.
OKY-T/3,T/5-D12 Series
Adjustable Output 3 and 5-Amp DOSA-SMT DC/DC Converters
MDC_OKY-T/3,T/5-D12 Series.B15 Page 8 of 21
www.murata-ps.com/support
Product Label
Because of the small size of these products, the product label contains a
character-reduced code to indicate the model number and manufacturing date
code. Not all items on the label are always used. Please note that the label dif-
fers from the product photograph on page 1. Here is the layout of the label:
The label contains three rows of information:
First row – Murata Power Solutions logo
Second row – Model number product code (see table)
Third row – Manufacturing date code and revision level
The manufacturing date code is four characters:
First character – Last digit of manufacturing year, example 2009
Second character – Month code (1 through 9 and O through D)
Third character – Day code (1 through 9 = 1 to 9, 10 = O and
11 through 31 = A through Z)
Fourth character – Manufacturing information
Figure 4. Label Artwork Layout
Y01003 Product code
Mfg.
date
code
Revision levelYMDX Rev.
Model Number Product Code
OKY-T/3-D12N-C Y00103
OKY-T/3-D12P-C Y01103
OKY-T/5-D12N-C Y00105
OKY-T/5-D12P-C Y01105
OKY-T/5-D12N-C-CIS
YC00105