Datasheet

PERFORMANCE DATA
OKX2-T/16-D12-C Maximum Current Temperature Derating at Sea Level
(VIN= 12V, VOUT = 1.8V).
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Ambient Temperature (ºC)
9.5
10
10.5
11
11.5
12
12.5
13
13.5
14
14.5
15
15.5
16
16.5
17
Output Current (Amps)
Natural convection
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25°C
(VOUT = 1.8V)
12345678910111213141516
70
75
80
85
90
VIN = 8.3V
V
IN = 12V
V
IN = 14V
Load Current (Amps)
Efficiency (%)
OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25°C
(VOUT = 2.5V)
12345678910111213141516
75
77
79
81
83
85
87
89
91
93
VIN = 8.3V
V
IN = 12V
V
IN = 14V
Load Current (Amps)
Efficiency (%)
OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25°C
(VOUT = 3.3V)
OKX2-T/16-D12-C Maximum Current Temperature Derating at Sea Level
(VIN= 12V, VOUT = 3.3V).
12345678910111213141516
75
77
79
81
83
85
87
89
91
93
95
VIN = 8.3V
V
IN = 12V
V
IN = 14V
Load Current (Amps)
Efficiency (%)
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
7
7.5
8
8.5
9
9.5
10
10.5
11
11.5
12
12.5
13
13.5
14
14.5
15
15.5
16
16.5
17
Ambient Temperature (ºC)
Output Current (Amps)
Natural convection
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
OKX T/10 & T/16-D12 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
MDC_OKX2_T10T16.B06 Page 9 of 16
www.murata-ps.com/support