Datasheet
FEATURES
600 KHz operation
4.5-14 Vdc input voltage range
Programmable output voltage from 0.591-6.0 VDC
Drives up to 200 F ceramic capacitive loads
High power conversion effi ciency at 93%
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control
SIP, 0.41 x 0.65 x 0.30 inches (10.4 x 16.5 x
7.62 mm).
Meets UL/EN/IEC 60950-1 safety certifi cation
RoHS-6 hazardous substance compliance
The OKR-T/6 series are miniature SIP non-isolated Point-of-Load (PoL) DC/DC power converters
measuring only 0.41 x 0.65 x 0.30 inches (10.4 x 16.5 x 7.62 mm). The wide input range is 4.5 to 14
Volts DC. Based on 600 KHz synchronous buck topology, the high power conversion effi cient Point of Load
(PoL) module features programmable output voltage and On/Off control, under voltage lock out (UVLO),
overcurrent and over temperature protections. These units meet all standard UL/EN/ IEC 60950-1 safety
certifi cations and RoHS-6 hazardous substance compliance.
PRODUCT OVERVIEW
Figure 1. Connection Diagram
Typical unit
External
DC
Power
Source
F1
On/Off
Control
Common
Common
Open = On
Closed = Off
+Vin +Vout
Trim
Controller
Reference and
Error Amplifier
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
(Positive
On/Off)
PRODUCT OVERVIEW
Typi
ca
l
un
i
t
OKR-T/6 Series
Adjustable Output 6-Amp SIP-mount DC/DC Converters
MDC_OKR-T/6-W12 Series.B06 Page 1 of 11
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs