Datasheet

OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS
Maximum Current Temperature Derating at Sea Level (Vin=7V, Vout=0.69V)
0
20 30 40 50 60 70 80 90
2
4
6
8
10
12
14
16
18
20
22
Output Current (Amps)
Ambient Temperature
(°C)
Natural Convection
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
Step Load Transient Response (Vin=7V, Vout=0.69V, Cload=188µF, Iout=10A to 20A)
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.
Step Load Transient Response (Vin=7V, Vout=0.69V, Cload=188µF, Iout=20A to 10A)
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.
Effi ciency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 0.69V)
0 4 8 12 16 20
75
80
85
90
70
95
Load Current (Amps)
Efciency (%)
VIN = 4.5V
V
IN = 5V
V
IN = 7V
Output Ripple and Noise (Vin=7V, Vout=0.69V, Iout=20A, Cload=188µF,
ScopeBW=20MHz) Trace1=Vout,10mV(AC)
On/Off Enable Delay (Vin=5.5V, Vout=0.69V, Iout=20A, Cload=188µF) Trace2=Enable,
5v/div, Trace1=Vout,200mV/div
OKL2-T/20-W12 Series
Programmable Output 20-Amp iLGA SMT PoL
DC-DC Converter Series
MDC_OKL2-T20-W12.B02 Page 11 of 19
www.murata-ps.com/support