FEATURES and OPTIONS, CONT. Conditions (1) Minimum Typical/Nominal Maximum Units
Tracking/Sequencing(optional)
Slew Rate 2 V/mS
Tracking Accuracy Rising input (0.5V/ms) ±100 mV
Tracking Accuracy Falling input (0.5V/ms) ±350 mV
Power Good Option
PGOOD, Open Drain Confi guration, Sinking:
Vout window for PGOOD: True -10% 10% Vset
Vout window for PGOOD: False 0.05 Vset
OUTPUT
Total Output Power 06066W
Voltage
Nominal Output Voltage Range (13) See trim formula 0.69 5.5 Vdc
Setting Accuracy At 50% load -1.5 1.5 % of Vnom.
Output Voltage Overshoot-Startup 3 % Vo set
Current
Output Current Range 01212A
Minimum Load No minimum load
Current Limit Inception (6) 98% of Vnom., after warmup 12.2 22 A
Short Circuit
Short Circuit Current (17)
Hiccup technique, autorecovery within ±1%
of Vout
0.02 A
Short Circuit Duration (remove short for
recovery)
Output shorted to ground, no damage Continuous
Short circuit protection method Current limiting
Regulation (10)
Total Regulation Band -2.5 Vo set 2.5 % Vo set
Line Regulation Vin=min. to max. Vout=nom. ±0.4 %
Load Regulation Iout=min. to max. ±0.4 %
Ripple and Noise (8)
5Vo, 12Vin 45 100
mV pk-pk
3.3Vo, 12Vin 25 60
1.8Vo, 12Vin 20 50
0.69Vo, 7Vin 15 40
Temperature Coeffi cient At all outputs ±0.02 % of Vnom./°C
Maximum Capacitive Loading (14)
Low ESR; >0.001, <0.01 ohm 188 1000 F
ESR > 0.01 ohm 5000 F
MECHANICAL
Outline Dimensions 0.8 x 0.45 x 0.34 Inches
20.32 x 11.43 x 8.55 mm
Weight 0.1 Ounces
2.78 Grams
ENVIRONMENTAL
Operating Ambient Temperature Range (9)
full power, all output voltages, see derating
curves
-40 85 ˚C
Storage Temperature Vin = Zero (no power) -55 125 ˚C
Thermal Protection/Shutdown Measured in center TBD ˚C
RoHS rating RoHS-6
FUNCTIONAL SPECIFICATIONS (CONT.)
Notes
(1) Specifi cations are typical at +25 °C, Vin = nominal (+12V), Vout = nominal (+5V), full load, external caps and
natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced
airfl ow. All models are tested and specifi ed with external 4×47F ceramic output capacitors and a 22 F external
input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test
equipment and may not be required to achieve specifi ed performance in your applications. However, Murata
Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec
under no-load conditions.
(2) Input Back Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering is Cin = 2 x
100 F ceramic, Cbus = 1000 F electrolytic, Lbus = 1 H.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airfl ow, the DC-DC converter will tolerate brief full current outputs if the total RMS
current over time does not exceed the Derating curve.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fi xed
conditions, Tpcboard = +25 ˚C, full output load, natural air convection.
(4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25oC., full output
load, natural convection.
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to
-Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed
+Vin.
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.
(7) Please observe the voltage input and output specifi cations in the voltage range graph.
(8) Output noise may be further reduced by adding an external fi lter. At zero output current, the output may contain
low frequency components which exceed the ripple specifi cation. The output may be operated indefi nitely with
no load.
(9) All models are fully operational and meet published specifi cations, including “cold start” at –40˚ C.
(10) Regulation specifi cations describe the deviation as the line input voltage or output load current is varied from a
nominal midpoint value to either extreme.