Datasheet

MECHANICAL SPECIFICATIONS
OKL-T/6-W12 Series
Programmable Output 6-Amp iLGA SMT PoLs
MDC_OKL-T/6-W12 Series.C02 Page 11 of 17
www.murata-ps.com/support
INPUT/OUTPUT CONNECTIONS
Pin Function
1 On/Off Control*
2VIN
3 Ground
4VOUT
5 Sense
6 Trim
7 Ground
8 No Connection
9 Sequence/Tracking**
10 Power Good Out
11 No Connection
12 No Connection
*The Remote On/Off can be provided with
either positive (P suffi x) or negative (N
suffi x) logic.
**OKL2 models only
Figure 3. OKL-T/6-W12 Mechanical Outline
Third Angle Projection
Dimensions are in inches (mm shown for ref. only).
Components are shown for reference only.
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 1˚
0.330 (8.38)
0
0.060 (1.52)
0.150 (3.81)
0.240 (6.10)
0.240 (6.10)
0.420 (10.67)
0
0.060 (1.52)
0.195 (4.95)
0.375 (9.53)
0.150 (3.81)
0.375 (9.53)
0.420 (10.67)
Bottom View
Top View
Side View
Bottom View
ViewEnd
0.48
(12.19)
0.48
(12.19)
0.283
(7.2)
max.
9
VinGnd
Vout
On/Off
Seq
NCGnd
NC
Trim
NC
Sense
1
24
5
11
6
12
10
3
87
PGood
0.50
12.7
0.50
12.7
0.135
3.43
0.090
2.29
0.180
4.57
0.090
2.29
0.180
4.57
0.090
2.29
0.180
4.57
0.045
1.14
0.135
3.43
0.180
4.57
1.27
0.050
(14 PLS)
12.40
0.488
12.40
0.488
0.070-0.080 [1.78-2.03mm]
x
0.160-0.170 [4.06-4.32mm]
3 PLACES
0.040-0.050 [1.02-1.27mm]
SQUARE PAD (9 PLS)
10
8712
6
11
5
432
1
Sense
NC
Trim1
NC
Gnd
PG
NC
Vout1
Gnd
Vin
C
L
C
L
Seq
9
On/Off
Copper Pads
No
Exposed
Copper
Permitted
Recommended Footprint
-through the Board-
Plating Thickness:
Gold overplate 1.18µ" (0.03µm)
on Nickel subplate 118.1µ" (3.0µm)
SOLDER PAD NOTES:
[1] To avoid incorrect contacts with exposed via’s and plated through holes on the bottom of the converter, do not have any
exposed copper around the unit aside from our recommended footprint. Except for connections to the pads, keep all external
circuits away from the board edges.
[2] Do not connect any additional components between the Trim pin and Vout or between the Trim and Sense pins. Use only
the specifi ed connections.