Datasheet
Connection Diagram
Figure 1. OKL2-T/6-W12
Note: Murata Power Solutions strongly recommends an external input fuse, F1. See specifi cations.
External
DC
Power
Source
F1
On/Off
Control
Common
Common
Sequence/Tracking Power Good out
Open = On
Closed = Off
+Vin +Vout
Trim
Sense
Controller
Reference and
Error Amplifier
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
(Positive
On/Off)
PRODUCT OVERVIEW
The OKL-T/6-W12 series are miniature non-iso-
lated Point-of-Load (PoL) DC/DC power converters
for embedded applications. Featuring inspectable
Land Grid Array (iLGA) format, the OKL-T/6-W12
measures only 0.48 x 0.48 x 0.283 inches max.
(12.2 x 12.2 x 7.2 mm max.).
The wide input range is 4.5 to 14 Volts DC.
The maximum output current is 6 Amps. Based
on fi xed-frequency synchronous buck converter
switching topology, the high power conversion
effi cient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, and
over-current protections.
An optional sequence/tracking feature on
OKL2-T/6-W12 models allows power sequencing
of PoL’s. These units meet all standard UL/EN/IEC
60950-1 safety certifi cations (2nd Edition) and RoHS-6
hazardous substance compliance.
FEATURES
■ iLGA inspectable Land Grid Array
■ 4.5-14Vdc input voltage range
■ Programmable output voltage from 0.591-5.5Vdc
■ Drives up to 300 µF ceramic capacitive loads
■ High power conversion effi ciency at 93%
■ Outstanding thermal derating performance
■ Short circuit and over current protection
■ On/Off control and Power Good signal
■ Optional Sequence/Tracking operation (OKL2-T/6-
W12 models)
■ Certifi ed to UL/EN/IEC 60950-1 safety, 2nd Edition
■ RoHS-6 hazardous substance compliance
OKL-T/6-W12 Series
Programmable Output 6-Amp iLGA SMT PoLs
MDC_OKL-T/6-W12 Series.C02 Page 1 of 17
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
Typical unit
T
ypica
l