Datasheet

The OKL-T/3-W5 series are miniature non-
isolated Point-of-Load (PoL) DC/DC power convert-
ers for embedded applications. The tiny form factor
is confi gured on a Land Grid Array (LGA) assembly
measuring only 0.48 x 0.48 x 0.244 inches max.
(12.2 x 12.2 x 6.2 mm max.).
The wide input range is 2.4 to 5.5 Volts DC.
The maximum output current is 3 Amps. Based
on fi xed-frequency synchronous buck converter
switching topology, the high power conversion
effi cient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, over-
current and over temperature protections.
An optional sequence/tracking feature allows
power sequencing of PoLs. These units are certi-
ed to all standard UL/EN/IEC 60950-1 safety
certifi cations (2nd Edition) and RoHS-6 hazardous
substance compliance.
PRODUCT OVERVIEW
Connection Diagram
Figure 1. OKL-T/3-W5
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifi cations.
External
DC
Power
Source
F1
On/Off
Control
Common
Common
Sequence/Tracking
(OKL2 models)
Power Good out
Open = On
Closed = Off
+Vin +Vout
Trim
Sense
Controller
Reference and
Error Amplifier
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
(Positive
On/Off)
FEATURES
iLGA inspectable Land Grid Array
2.4-5.5Vdc input voltage range
Programmable output voltage from 0.6-3.63Vdc
Drives 200 µF ceramic capacitive loads
High power conversion effi ciency at 95.3%
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control
Certifi ed to UL/EN/IEC 60950-1 safety, 2nd Edition
RoHS-6 hazardous substance compliance
Sequence/Tracking operation (optional)
Typical unit
OKL-T/3-W5 Series
Programmable Output 3-Amp iLGA SMT PoLs
MDC_OKL-T/3-W5 Series.C02 Page 1 of 17