Datasheet
OKL-T/3-W12 PERFORMANCE DATA AND OSCILLOGRAMS
OKL-T/3-W12 Maximum Current Temperature Derating at Sea Level
(VIN = 12V, VOUT = 5V)
20 30 40 50 60 70 80 90
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Natural convection
100 LFM
Output Current (Amps)
Ambient Temperature (ºC)
On/Off Enable Startup Delay (Vin=12V, Vout=5.0V, Iout=3A, Cload=0)
Trace 4=Enable In, Trace2=Vout
Output Ripple and Noise (Vin=12V, Vout=5.0V, Iout=3A, Cload=0, ScopeBW=20MHz)
Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=0, Iout=1.5A to 3A)
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div.
Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=0, Iout=3A to 1.5A)
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div.
OKL2-T/3-W12 Effi ciency vs. Line Voltage and Load Current +25 ˚C
(Vout = 5V)
01 23
100
95
90
85
80
75
70
65
Load Current (Amps)
Efficiency (%)
VIN = 6V
V
IN = 12V
V
IN = 14V
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
MDC_OKL-T/3-W12 Series.C02 Page 5 of 17
www.murata-ps.com/support