OKL-T/1-W12 Series www.murata-ps.com Programmable Output 1-Amp iLGA SMT PoLs PRODUCT OVERVIEW Typical unit The OKL-T/1-W12 series are non-isolated Pointof-Load (PoL) DC/DC power converters for embedded applications. Featuring inspectable Land Grid Array (iLGA) format, the OKL-T/1-W12 measures only 0.488 x 0.488 x 0.18 inches max. (12.4 x 12.4 x 4.57 mm max.). The wide input range is 2.9 to 14 Volts DC. The maximum output current is 1 Amp.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Model Number Output Input Package - Pinout P83 Efficiency On/Off Regulation (max.) Vout Iout (Amps, Power R/N (mV p-p) Vin nom. Range Iin, no load Iin, full load Case C83 Polarity (Volts) ➀ max.) (Watts) Max. ➃ (Volts) (Volts) (mA) ➃ (Amps) ➁ Min. Typ. inches (mm) Line Load OKL-T/1-W12P-C 0.9-5.5 1 5 10 ±0.25% ±0.25% 12 2.9-14 10 0.46 88.7% 90% Pos. 0.488x0.488x0.18 max 12.4x12.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs Performance and Functional Specifications Environmental See Note 1 Calculated MTBF (hours) Telecordia method (4a) Calculated MTBF (hours) MIL-HDBK-217N2 method (4b) Input Input Voltage Range Isolation Start-Up Voltage Undervoltage Shutdown (see Note 15) Overvoltage Shutdown Reflected (Back) Ripple Current (Note 2) Internal Input Filter Type Recommended External Fuse Reverse Polarity Protection See Ordering Guide and Note 7. Not isolated 2.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs Specification Notes, Cont.: (7) Please observe the voltage input and output specifications in the Voltage Range Graph on page 7. (8) Output noise may be further reduced by adding an external filter. At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load. Due to the minimum duty cycle of the controller, operation below Vout=1.8V.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 5V) Maximum Current Temperature Derating at Sea Level (Vin = 6V, Vout = 5V, airflow is from pad 10 to pad 1) 120 1.20 1.10 100 1.00 65 LFM 0.90 Output Current (Amps) Efficiency (%) 80 VIN = 6.5V 60 VIN = 12V VIN = 14V 40 0.80 0.70 0.60 0.50 0.40 0.30 20 0.20 0.10 0 0 0.2 0.4 0.6 0.8 0.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Output Ripple and Noise (Vin=14V, Vout=3.3V, Iout=1A, Cload=0, Ta=+25°C., ScopeBW=100MHz) Step Load Transient Response (Vin=4.5V, Vout=3.3V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.)Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Step Load Transient Response (Vin=4.5V, Vout=3.3V, Cload=0, Iout=1A to 0.5A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Step Load Transient Response (Vin=14V, Vout=3.3V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Step Load Transient Response (Vin=14V, Vout=3.3V, Cload=0, Iout=1A to 0.5A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 2.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Output Ripple and Noise (Vin=14V, Vout=2.5V, Iout=1A, Cload=0, Ta=+25°C., ScopeBW=100MHz) Step Load Transient Response (Vin=3.5V, Vout=2.5V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Step Load Transient Response (Vin=3.5V, Vout=2.5V, Cload=0, Iout=1A to 0.5A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Step Load Transient Response (Vin=14V, Vout=2.5V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Step Load Transient Response (Vin=14V, Vout=2.5V, Cload=0, Iout=1A to 0.5A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 1.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Output Ripple and Noise (Vin=2.6V, Vout=0.9V, Iout=1A, Cload=0, Ta=+25°C., ScopeBW=100MHz) Output Ripple and Noise (Vin=12V, Vout=0.9V, Iout=1A, Cload=0, Ta=+25°C., ScopeBW=100MHz) Output Ripple and Noise (Vin=14V, Vout=0.9V, Iout=1A, Cload=0, Ta=+25°C., ScopeBW=100MHz) Step Load Transient Response (Vin=2.6V, Vout=0.9V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS Step Load Transient Response (Vin=12V, Vout=0.9V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Step Load Transient Response (Vin=12V, Vout=0.9V, Cload=0, Iout=1A to 0.5A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div. Step Load Transient Response (Vin=14V, Vout=0.9V, Cload=0, Iout=0.5A to 1A, Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs MECHANICAL SPECIFICATIONS Vacuum pickup nozzle location 12.4 0.49 5.0 0.20 4.6 0.18 MAX 5.0 0.20 12.4 0.49 Nozzle dia. 4.00 .157 typ. Top View Side View Bottom View SMT (iLGA Surface Mount Package) (MSL Rating 2) Pinouts and Pin Locations CL 3.43 0.135 1.14 0.045 3 CL 2 Gnd 4 3.43 0.135 4.57 0.180 5 11 6 Vin Vout1 12.40 0.488 REF 1.78 0.070 TYP On/Off NC 10 NC Gnd NC Gnd NC Trim1 12 2.29 0.090 7 CL 8 1 NC 2.29 0.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs MECHANICAL SPECIFICATIONS, Continued Recommended Footprint (Through the Board) 12.7 .50 4.57 .180 3.43 .135 4 12.7 .50 1 2.29 .090 10 9 1.14 .045 3 2 1.27 .050 (14 PLS) Gnd Vout1 Vin 4.57 .180 .070-.080 [1.78-2.03mm] x .160-.170 [4.06-4.32mm] 3 PLACES On/Off NC 5 PG Gnd 11 Trim2 Gnd 8 7 Vout2 Trim1 3.43 .135 12.40 .488 CL 4.57 .180 6 Sync 12 2.29 .090 .040-.050 [1.02-1.27mm] SQUARE PAD (9 PLS) 4.57 .180 CL 12.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs TAPE AND REEL INFORMATION (MSL RATING 2) 330.20 13.000 FEED (UNWIND) DIRECTION 10.44 0.411 5.00 0.197 REF 5.00 0.197 REF 4.00 0.157 0.77 0.030 2.00 0.079 1.50 0.059 TYP 1.75 0.069 13.41 0.528 24.00 0.945 NOZZLE DIA. 4.00 0.157 TYP. 16.00 0.63 PITCH Contents: 800 units per reel TOP COVER TAPE 5.00 0.197 Dimensions in inches [mm] www.murata-ps.com/support MDC_OKL-T/1-W12 Series.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs TECHNICAL NOTES Output Voltage Adustment The output voltage may be adjusted over a limited range by connecting an external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim resistor is recommended to have a ±0.5% accuracy (or better) with low temperature coefficient, ±100 ppm/°C or better. Mount the resistor close to the converter with very short leads or use a surface mount trim resistor.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs Input Ripple Current and Output Noise All models in this converter series are tested and specified for input reflected ripple current and output noise using designated external input/ output components, circuits and layout as shown in the figures below. The Cbus and Lbus components simulate a typical DC voltage bus. Please note that the values of Cin, Lbus and Cbus will vary according to the specific converter model.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs Remote On/Off Control The OKL Series power modules can be specified with either a positive or negative logic polarity. See Figures 7 and 8 for On/Off circuit control. In the positive logic on/off option the unit turns on during a logic high on the On/Off pin and turns off during a logic low. In a negative logic on/off option, the unit turns off during logic high and on during logic low. The On/Off signal should always be reference to ground.
OKL-T/1-W12 Series Programmable Output 1-Amp iLGA SMT PoLs Vertical Wind Tunnel IR Transparent optical window Unit under test (UUT) Variable speed fan Murata Power Solutions employs a computer controlled custom-designed closed loop vertical wind tunnel, infrared video camera system, and test instrumentation for accurate airflow and heat dissipation analysis of power products.