Datasheet

Designation Cmd Impl
TON_RISE 61h Yes
TOFF_DELAY 64h Yes
TOFF_FALL 65h Yes
TON_MAX_FAULT_LIMIT 62h No
Status Commands (Read Only)
CLEAR_FAULTS 03h Yes
STATUS_BYTE 78h Yes
STATUS_WORD 79h Yes
STATUS_VOUT 7Ah Yes
STATUS_IOUT 7Bh Yes
STATUS_INPUT 7Ch Yes
STATUS_TEMPERATURE 7Dh Yes
STATUS_CML 7Eh Yes
STATUS_MFR_SPECIFIC 80h Yes
Monitor Commands (Read Only
READ_VIN 88h Yes
READ_VOUT 8Bh Yes
READ_IOUT 8Ch Yes
READ_TEMPERATURE_1 8Dh Yes
READ_TEMPERATURE_2 8Eh No
READ_FAN_SPEED_1 90h No
READ_DUTY_CYCLE 94h Yes
READ_FREQUENCY 95h Yes
Group Commands
INTERLEAVE 37h Yes
PHASE_CONTROL F0h Yes
Identifi cation Commands
PMBUS_REVISION 98h Yes
MFR_ID 99h Yes
MFR_MODEL 9Ah Yes
MFR_REVISION 9Bh Yes
MFR_LOCATION 9Ch Yes
MFR_DATE 9Dh Yes
MFR_SERIAL 9Eh Yes
Supervisory Commands
STORE_DEFAULT_ALL 11h Yes
RESTORE_DEFAULT_ALL 12h Yes
STORE_USER_ALL 15h Yes
RESTORE_USER_ALL 16h Yes
Product Specifi c Commands
Output Commands
XTEMP_SCALE D9h No
XTEMP_OFFSET DAh No
Time Setting Commands
POWER_GOOD_DELAY D4h Yes
Fault limit Commands
IOUT_AVG_OC_FAULT_LIMIT E7h Yes
IOUT_AVG_UC_FAULT_LIMIT E8h Yes
Fault Response Commands
MFR_IOUT_OC_FAULT_RESPONSE E5h Yes
MFR_IOUT_UC_FAULT_RESPONSE E6h Yes
OVUV_CONFIG D8h Yes
Confi guration and Control Commands
MFR_CONFIG D0h Yes
USER_CONFIG D1h Yes
MISC_CONFIG E9h Yes
TRACK_CONFIG E1h Yes
PID_TAPS D5h Yes
PID_TAPS_CALC
*
F2h Yes
INDUCTOR D6h Yes
NLR_CONFIG D7h Yes
PMBus Commands
The products are PMBus compliant. The following table lists the
implemented PMBus read commands. For more detailed information
see PMBus Power System Management Protocol Specifi cation; Part I
– General Requirements, Transport and Electrical Interface and PMBus
Power System Management Protocol; Part II – Command Language.
Designation Cmd Impl
Standard PMBus Commands
Control Commands
PAGE 00h No
OPERATION 01h Yes
ON_OFF_CONFIG 02h Yes
WRITE_PROTECT 10h No
Output Commands
VOUT_MODE (Read Only) 20h Yes
VOUT_COMMAND 21h Yes
VOUT_TRIM 22h Yes
VOUT_CAL_OFFSET 23h Yes
VOUT_MAX 24h Yes
VOUT_MARGIN_HIGH 25h Yes
VOUT_MARGIN_LOW 26h Yes
VOUT_TRANSITION_RATE 27h Yes
VOUT_DROOP 28h Yes
MAX_DUTY 32h Yes
FREQUENCY_SWITCH 33h Yes
VIN_ON 35h No
VIN_OFF 36h No
IOUT_CAL_GAIN 38h Yes
IOUT_CAL_OFFSET 39h Yes
VOUT_SCALE_LOOP 29h No
VOUT_SCALE_MONITOR 2Ah No
COEFFICIENTS 30h No
Fault Limit Commands
POWER_GOOD_ON 5Eh Yes
POWER_GOOD_OFF 5Fh No
VOUT_OV_FAULT_LIMIT 40h Yes
VOUT_OV_WARN_LIMIT 42h No
VOUT_UV_WARN_LIMIT 43h No
VOUT_UV_FAULT_LIMIT 44h Yes
IOUT_OC_FAULT_LIMIT 46h Yes
IOUT_OC_WARN_LIMIT 4Ah No
IOUT_UC_FAULT_LIMIT 4Bh Yes
OT_FAULT_LIMIT 4Fh Yes
OT_WARN_LIMIT 51h Yes
UT_WARN_LIMIT 52h Yes
UT_FAULT_LIMIT 53h Yes
VIN_OV_FAULT_LIMIT 55h Yes
VIN_OV_WARN_LIMIT 57h Yes
VIN_UV_WARN_LIMIT 58h Yes
VIN_UV_FAULT_LIMIT 59h Yes
Fault Response Commands
VOUT_OV_FAULT_RESPONSE 41h Yes
VOUT_UV_FAULT_RESPONSE 45h Yes
OT_FAULT_RESPONSE 50h Yes
UT_FAULT_RESPONSE 54h Yes
VIN_OV_FAULT_RESPONSE 56h Yes
VIN_UV_FAULT_RESPONSE 5Ah Yes
IOUT_OC_FAULT_RESPONSE 47h No
IOUT_UC_FAULT_RESPONSE 4Ch No
Time setting Commands
TON_DELAY 60h Yes
OKDx-T/50-W12-C
50A Digital PoL DC-DC Converter Series
MDC_OKDx-T/50-W12-C.A04 Page 34 of 41
www.murata-ps.com/support