Datasheet

Shut-down by input source
Typical Characteristics
Start-up and shut-down
Start-up by input source
Start-up enabled by connecting V
I
at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
C
O
= 470 μF/10 m, I
O
= 50 A
Top trace: output voltage (0.5 V/div.).
Bottom trace: input voltage (5 V/div.).
Time scale: (20 ms/div.).
Shut-down enabled by disconnecting
V
I
at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
C
O
= 470 μF/10 m, I
O
= 50 A
Start-up by CTRL signal Shut-down by CTRL signal
Top trace: output voltage (0.5 V/div.).
Bottom trace: input voltage (5 V/div.).
Time scale: (2 ms/div.).
Start-up by enabling CTRL signal at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
C
O
= 470 μF/10 m, I
O
= 50 A
Top trace: output voltage (0.5 V/div.).
Bottom trace: CTRL signal (2 V/div.).
Time scale: (20 ms/div.).
Shut-down enabled by disconnecting
V
I
at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
C
O
= 470 μF/10 m, I
O
= 50 A
Top trace: output voltage (0.5 V/div).
Bottom trace: CTRL signal (2 V/div.).
Time scale: (2 ms/div.).
OKDx-T/50-W12-C
50A Digital PoL DC-DC Converter Series
MDC_OKDx-T/50-W12-C.A04 Page 10 of 41
www.murata-ps.com/support