Datasheet
PART NUMBER STRUCTURE
PM
FEATURES
Small package: SMD/TH: 30.85 x 20.0 x 8.2 mm
(1.215 x 0.787 x 0.323 in); SIP: 33.0 x 7.6 x 18.1 mm
(1.30 x 0.30 x 0.713 in)
0.6 V - 3.3 V output voltage range
High effi ciency, typ. 97.2% at 5Vin, 3.3Vout half
load
Confi guration and monitoring via PMBus™
Adaptive compensation of PWM control loop &
fast loop transient response
Synchonization & phase spreading
Current sharing, voltage tracking & voltage
margining
Voltage setting via pin-strap or PMBus™
MTBF 14.2 Mh
Non-Linear Response for reduction of decou-
pling capacitor
Remote control & power good
Output short-circuit, output over voltage, & over
temperature protection
Certifi ed to UL/IEC 60950-1
Typical units
PRODUCT OVERVIEW
The OKDx-T/50-W12 series are high effi -
ciency, digital point-of-Load (PoL) DC-DC
power converters capable of delivering
50A/165W. Available in three different pack-
age formats, through-hole, single-in-line,
and surface mount, these converters have a
typical effi ciency of 97.2%. PMBus™ compat-
ibility allows monitoring and confi guration of
critical system-level performance require-
ments. Apart from standard PoL performance
and safety features like OVP, OCP, OTP, and
UVLO, these digital converters have advanced
features: digital current sharing (full power,
no derating), non-linear transient response,
optimized dead time control, synchronization,
and phase spreading. These converters are
ideal for use in telecommunications, network-
ing, and distributed power applications.
Power Management via PMBus™
Confi gurable soft-start/stop
Confi gurable output voltage (Vout) and voltage
margins (Margin low and Margin high)
Confi gurable protection limits for OVP, input over
voltage, input under voltage, over current, on/off,
and temperature
Status monitor Vout, Iout, Vin, Temp, Power
good, and On/Off
Applications
Distributed power architectures
Intermediate bus voltage applications
Servers and storage applications
Network equipment
Trimmable Output
Voltage Range
0.6 - 3.3Vdc
- T
Y = Surface Mount
H = Horizontal Mount Through-Hole
X = SIP
x
Digital Non-isolated PoL
OKD C-
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption
7b – lead in solder)
Maximum Rated Output
Current in Amps
/ 50
Input Voltage Range
4.5-14Vdc
W12-
Software Confi guration Digits
(001 is positive turn-on logic)
(002 is negative turn-on logic)*
xxx-
T
ypical unit
s
Long pin length (5.5mm)
E
*Special quantity order is required;
contact Murata Power Solutions for
MOQ and lead times.
OKDx-T/50-W12-C
50A Digital PoL DC-DC Converter Series
MDC_OKDx-T/50-W12-C.A04 Page 1 of 41
www.murata-ps.com
www.murata-ps.com/support