Datasheet

NDTS Series
Isolated 3W Single Output DC/DC Converters
KDC_NDTS.D06 Page 4 of 6
www.murata-ps.com/support
APPLICATION NOTES (continued)
Minimum Load
The minimum load for correct operation is 25% of the full rated load across the specified input voltage range. Lower loads may cause a significant increase in output ripple and
may cause the output voltage to exceed its specification transiently during power-down when the input voltage also falls below its rated minimum.
The following graphs show the typical required minimum load required for stable operation in mA verses input voltage. Some variants are not included as they do not typically
require a minimum load for stable operation: NDTD1212C, and NDTD1215C.
The NDTS series will operate from a wider input range than specified in the input characteristics datasheet table with output power derating. Please contact Murata Power
Solutions for further information.
NDTS05XXC
NDTS12XXC
0
20
40
60
80
100
120
140
160
180
200
4.5 5.5 6.5 7.5 8.5 9.5 10.5 11.5
Input Voltage (V)
Minimum Load (mA)
0503
0505
0512
0515
9 111315171921
Input Voltage (V)
Minimum Load (mA)
1203
1205
0
10
20
30
40
50
60
70
80
90
100