Datasheet

NDTD Series
Isolated 3W Wide Input Dual Output DC/DC Converters
KDC_NDTD.E05 Page 4 of 7
www.murata-ps.com/support
APPLICATION NOTES (continued)
Minimum Load
The minimum load for correct operation is 25% of the full rated load across the specified input voltage range. Lower loads may cause a significant increase in output ripple and
may cause the output voltage to exceed its specification transiently during power-down when the input voltage also falls below its rated minimum.
The following graphs show the typical required minimum load required for stable operation in mA verses input voltage. Some variants are not included as they do not typically
require a minimum load for stable operation: NDTD0512C, NDTD0515C, NDTD1212C, and NDTD1215C.
NDTD05XXC
NDTD12XXC
0
5
10
15
20
25
30
35
40
45
6789
Input Voltage (V)
Minimum Load (mA)
0503
0505
0
5
10
15
20
25
30
35
40
45
50
6 8 10 12 14 16 18
Input Voltage (V)
Minimum Load (mA)
1203