SELECTION GUIDE
Order Code
Nominal Input
Voltage
Output
Voltage
Output Current
Input Current at
Rated Load
Load Regulation
(Typ)
Load Regulation
(Max)
Ripple & Noise
(Typ)
1
Ripple & Noise
(Max)
1
Efficiency (Min.)
Efficiency (Typ.)
Isolation
Capacitance
MTTF
2
V V mA mA % mVp-p % % pF kHrs
MEV3S0505SC 5 5 600 700 6.8 8 39 50 81.5 83 28 6029
MEV3S0509SC 5 9 333 680 5.5 7 24 35 85.3 87 43 5163
MEV3S0512SC 5 12 250 700 5 7 20 35 81.5 85.5 32 5995
MEV3S0515SC 5 15 200 700 5 6 18 30 85 87.5 40 5426
MEV3S1205SC 12 5 600 300 4.5 6 34 50 81.5 84 34 6063
MEV3S1209SC 12 9 333 280 3.6 5 22 35 85.5 87.5 50 6056
MEV3S1212SC 12 12 250 280 3.2 4.5 16 30 86 88 63 6572
MEV3S1215SC 12 15 200 280 2.8 4 13 30 87 89 70 5754
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
Continuous operation, 5V input types 4.5 5 5.5
V
Continuous operation, 12V input types 10.8 12 13.2
Reflected ripple current
5V input types 8 18
mA p-p
12V input types 6.5 15
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power
T
A=-40°C to 85°C
3 W
Voltage Set Point Accuracy See tolerance envelope
Line regulation High V
IN to low VIN 1.01 1.1 %/%
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage Flash tested for 1 minute 3000 VDC
Resistance Viso= 1000VDC 10 GΩ
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Switching frequency 60 kHz
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification All output types -40 85
°C
Storage -50 125
Case Temperature rise
above ambient
MEV3S0505SC 37
All other types 35
Cooling Free air convection
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1mm from case for 10 seconds 260°C
Internal power dissipation 700mW
Input voltage V
IN, MEV05 types 7V
Input voltage V
IN, MEV12 types 15V
PRODUCT OVERVIEW
The MEV3 series is a new range of high
performance 3W DC/DC converters, offering 3W
of available output power in a previously rated
2W package capable of operation over the full
industrial temperature range of -40ºC to 85ºC.
Available in an industry standard SIP package,
with a pin compatible power upgrade path from
the 1W NMV/MEV and 2W NMK series’, they
are ideally suited for providing local supplies on
control system boards with the added benefit of
3kVDC galvanic isolation.
FEATURES
n UL 60950 recognised
n RoHS compliant
n Typical efficiency from 83%
n Power density 1.9W/cm
3
n Wide temperature performance at full
3 Watt load, –40°C to 85°C
n UL 94V-0 package material
n No heatsink required
n Industry standard pinout
n 3kVDC isolation (1 minute)
n 5V & 12V input
n 5V, 9V, 12V, & 15V output
n Fully encapsulated with toroidal
magnetics
n No external components required
n No electrolytic or tantalum capacitors
1. See Ripple & Noise characterisation method.
2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load.
All specifications typical at T
A=25°C, nominal input voltage and rated output current unless otherwise specified.