Datasheet
LXDC2UR series
Micro DC-DC converter
13
Dec 2014
No.
Items Specifications Test Methods QTY
Result
(NG)
6 High Temp.
Exposure
Appearance
Electrical
specifications
No severe damages
Satisfy
specifications listed
in paragraph 6-2.
Temperature:85±2 ℃
Period:1000+48/-0 h
Room Condition:2~24h
18
G
(0)
7 Temperature
Cycle
Condition:100 cycles in the following
table
Step
Temp(°C) Time(min)
1
Min.
Operating
Temp.+0/-3
30±3
2
Max.
Operating
Temp.+3/-0
30±3
18
G
(0)
8 Humidity
(Steady State)
Temperature:85±2 ℃
Humidity:80~90%RH
Period:1000+48/-0 h
Room Condition:2~24h
18
G
(0)
9 Low Temp.
Exposure
Temperature:-40±2 ℃
Period:1000+48/-0 h
Room Condition:2~24h
18
G
(0)
10
ESD(Machine
Model)
C:200pF、R:0Ω
TEST Voltage :+/-100V
Number of electric discharges:1
5
G
(0)
11
ESD(Human
Body Model)
C:100pF、R:1500Ω
TEST Voltage :+/-1000V
Number of electric discharges:1
5
G
(0)