Datasheet
TYPICAL PERFORMANCE DATA
Maximum Current Temperature Derating vs. Airfl ow (Vin=Vnom., airfl ow direction is
from -Vin to +Vin, with baseplate, at sea level)
0
5
10
15
20
25
30
30 35 40 45 50 55 60 65 70 75 80 85
Output Current (Amps)
Ambient Temperature
(°C)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
Maximum Current Temperature Derating vs. Airfl ow (Vin=Vnom., airfl ow direction is
from Vin to Vout, no baseplate, at sea level)
0
5
10
15
20
25
30
30 35 40 45 50 55 60 65 70 75 80 85
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
Output Current (Amps)
Ambient Temperature
(°C)
Output Voltage vs Load Current at +60°C. Output Voltage vs Load Current at +25°C.
01020
0
2
4
6
9
10
12
V
IN
= 36V, 48V, 75V
Output (Volts)
Load (Amps)
01020
0
2
4
6
9
10
12
V
IN
= 36V, 48V, 75V
Output (Volts)
Load (Amps)
HPQ-12/25-D48 Series
Isolated 300-Watt Quarter Brick DC-DC Converters
MDC_HPQ-12/25-D48 Series.B07 Page 6 of 16