Datasheet
www.murata-ps.com/support
PRELIMINARY
DBQ0360V2 FUNCTIONAL SPECIFICATIONS (CONT.)
MECHANICAL
Conditions ➀
Minimum Typical/Nominal Maximum Units
Outline Dimensions (open frame)
2.3 x 1.45 x 0.48
Inches
(Please refer to outline drawing) L x W x H
58.4 x 36.83 x 12.19
mm
Outline Dimensions (with baseplate)
2.3 x 1.45 x 0.50
Inches
58.4 x 36.80 x 12.7
mm
Weight (open frame)
TBD
Ounces
Grams
Weight (with baseplate)
TBD
Ounces
Grams
Through Hole Pin Diameter
0.04 & 0.062
Inches
1.016 & 1.575
mm
Digital Interface Pin Diameter
0.02
0.5
Through Hole Pin Material
Copper alloy
TH Pin Plating Metal and Thickness Nickel subplate
98.4-299
µ-inches
Gold overplate
4.7-19.6
µ-inches
ENVIRONMENTAL
Operating Ambient Temperature Range with derating -40
85 °C
Operating Baseplate Temperature
-40
110 °C
Storage Temperature Vin = Zero (no power) -55
125 °C
Thermal Protection/Shutdown (with “B” Suffi x,
default value, Confi gurable via PMBUS)
Confi gurable Via PMBus
120
°C
Electromagnetic Interference External fi lter required; see
B
Class
Conducted, EN55022/CISPR22 emissions performance test.
RoHS rating
RoHS-6
Notes
➀ Typical at TA = +25°C under nominal line voltage and full-load conditions. All models are speci-
fi ed with external 1F and 10F capacitors in parallel across their output pins. All values are
default, unless otherwise noted.
➁ Over-current protection is non-latching with auto recovery (hiccup).
➂ Regulation specifi cations describe the output voltage changes as the line voltage or load current
is varied from its nominal or midpoint value to either extreme.
➃ See Operating information section.
DBQ/DVQ Series
420W Digital Fully Regulated Intermediate
DC-DC Bus Converter
MDC_DBQ Series.B02Δ Page 6 of 31