Datasheet
www.murata-ps.com/support
Notes
➀ Typical at TA = +25°C under nominal line voltage and full-load conditions. All models are speci-
fi ed with external 1F and 10F capacitors in parallel across their output pins. All values are
default, unless otherwise noted.
➁ Over-current protection is non-latching with auto recovery (hiccup).
➂ Regulation specifi cations describe the output voltage changes as the line voltage or load current
is varied from its nominal or midpoint value to either extreme.
➃ See Operating information section.
MECHANICAL
Conditions ➀
Minimum Typical/Nominal Maximum Units
Outline Dimensions (open frame) 2.3 x 1.45 x 0.48 Inches
(Please refer to outline drawing) L x W x H 58.4 x 36.83 x 12.19 mm
Outline Dimensions (with baseplate) 2.3 x 1.45 x 0.52 Inches
58.4 x 36.80 x 13.21 mm
Weight (open frame) 1.85 Ounces
52.5 Grams
Weight (with baseplate) 2.35 Ounces
66.8 Grams
Through Hole Pin Diameter 0.04 & 0.062 Inches
1.016 & 1.575 mm
Digital Interface Pin Diameter 0.020
0.5
Through Hole Pin Material Copper alloy
TH Pin Plating Metal and Thickness Nickel subplate 98.4-299 µ-inches
Gold overplate 4.7-19.6 µ-inches
ENVIRONMENTAL
Operating Ambient Temperature Range with derating -40 85 °C
Operating Baseplate Temperature -40 110 °C
Storage Temperature Vin = Zero (no power) -55 125 °C
Thermal Protection/Shutdown (with "B" Suffi x,
default value, Confi gurable via PMBus)
Confi gurable Via PMBus 125 °C
Electromagnetic Interference
Conducted, EN55022/CISPR22
External fi lter required; see
emissions performance test.
B Class
RoHS rating RoHS-6
DBQ0135V2 FUNCTIONAL SPECIFICATIONS (CONT.)
DBQ/DVQ Series
420W Digital Fully Regulated Intermediate
DC-DC Bus Converter
MDC_DBQ Series.B02Δ Page 15 of 31