Datasheet
DRQ-12/42-D48 Series
500W Digital Fully Regulated
Intermediate DC-DC Bus Converter
MDC_DRQ-12/42-D48.A03 Page 5 of 24
www.murata-ps.com/support
PERFORMANCE DATA
Maximum Current Temperature Derating at sea level
(Vin = 40V, airfl ow from -Vin to +Vin, with heat sink)
Maximum Current Temperature Derating at sea level
(Vin = 75V, airfl ow from -Vin to +Vin, with heat sink)
Output vs. Input Voltage @ No Load
Maximum Current Temperature Derating at sea level
(Vin = 48V, airfl ow from -Vin to +Vin, with heat sink)
30 35 40 45 50 55 60 65 70 75 80 85
0
10
20
30
40
50
Output Current (Amps)
Ambient Temperature
(°C)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
1.0 m/s (200 LFM)
0.5 m/s (100 LFM)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
34.1
34.5
34.9
35.3
35.7
36.1
36.5
36.9
37.3
37.7
38.1
38.5
38.9
Output Voltage
VIN OFF
VIN ON
30 35 40 45 50 55 60 65 70 75 80 85
0
10
20
30
40
50
Output Current (Amps)
Ambient Temperature
(°C)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
1.0 m/s (200 LFM)
0.5 m/s (100 LFM)
30 35 40 45 50 55 60 65 70 75 80 85
0
10
20
30
40
50
Output Current (Amps)
Ambient Temperature
(°C)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
1.0 m/s (200 LFM)
0.5 m/s (100 LFM)
Effi ciency vs. Line Voltage and Load Current @ +25°C
70
75
80
85
90
95
100
0 1020304050
Load Curre nt (Amps)
Efficiency (%)
V
IN
= 38V
V
IN
= 48V
V
IN
= 75V