Datasheet

Please refer to the part number structure for additional ordering information and options.
All specifi cations are typical at nominal line voltage and full load, +25°C unless otherwise noted. See
detailed specifi cations. Output capacitors are 1 µF || 10 µF. These caps are necessary for our test equip-
ment and may not be needed for your application.
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ ➁
Root Model
Output Input
Effi ciency Dimensions with baseplate
VOUT
(Volts,
max.)
IOUT
(Amps,
max.)
Power
(Watts,
max.)
R/N (mV
pk-pk)
Regulation
(mV, max.)
VIN Nom.
(Volts)
Range
(Volts)
IIN no
load (mA)
IIN full
load
(Amps)Typ. Max. Line Load Typ. (inches) (mm)
DRQ-12/42-D48
DRQ-12/42-D48 11.85 43.5 515.5 80 120 100 100 48 38-75 130 11.39 95.5%
2.3 x 1.45 x 0.52
2.3 x 1.45 x 0.52
58.4 x 36.8 x 13.21
58.4 x 36.8 x 13.21
PART NUMBER STRUCTURE
Pin length option
Blank = Standard pin length 0.180 in. (4.6 mm)
L1 = 0.110 in. (2.79 mm)
L2 = 0.145 in. (3.68 mm)
Lx
Input Voltage Range:
D48 = 38-75 Volts (48V nominal)
/
12 42
-
-
DRQ
Digital Regulated
Quarter-brick
RoHS Hazardous Materials compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard
-
C
Complete Model Number Example:
Negative On/Off logic, Integrated Heat Sink installed, 0.110˝ pin length, RoHS-6 compliance
DRQ-12/42-D48NKL1-C
Nominal Output Voltage
Maximum Rated Output
Current in Amps
N
On/Off Control Logic
N = Negative logic
P = Positive logic
Baseplate or Integrated Heat Sink (optional)
B = Baseplate installed
K = Integrated Heat Sink
B
A = PMBus™ (ABC 16-pin pinout)
Blank = No PMBus™ (DOSA 5-pin pinout)
A
D48
Special quantity order is required; samples available with standard pin length only.
Some model number combinations may not be available. See website or contact your local Murata sales representative.
DRQ-12/42-D48 Series
500W Digital Fully Regulated
Intermediate DC-DC Bus Converter
MDC_DRQ-12/42-D48.A03 Page 2 of 24
www.murata-ps.com/support