Datasheet

Dual Output BWR Models
Mixed Voltage, 5V AND 3.3V, 2” x 2”
33 Watt DC/DC Converters
MDC_BWR 33W Models.A05 Page 1 of 12
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
FEATURES

Regulated 3.3V and 5V outputs

5V @ 6Amps/3.3V @ 7 Amps capability

33 Watts total output power

No-load operation

Available input voltage ranges:
10-18V, 18-36V or 36-75V

Small 2" x 2" x 0.45" package

UL1950 and EN60950-1 safety approvals
mark available (75V-input models)

Continuous short-circuit protection

Fully isolated, 1500Vdc guaranteed

–40 to +100°C operating temperature

Input under and overvoltage shutdown

Output overvoltage protection

Thermal shutdowns
Figure 1. Simplifi ed Schematic
+INPUT
(1)
–INPUT
(2)
SWITCH
CONTROL
+5V OUTPUT
(5)
+3.3V OUTPUT
(7)
OUTPUT
RETURN
(6)
TRIM
(8)
PWM
CONTROLLER
REFERENCE &
ERROR AMP
OPTO
ISOLATION
ON/OFF
CONTROL
(4)
UV & OV
COMPARATORS
ACTIVE
BLEEDER
THERMAL
SHUTDOWN
For applications requiring 33 watts of power from
5V and 3.3V, DATEL offers a new power sharing
DC/DC converter capable of meeting your output
current requirements. The BWR-5/6-3.3/7-D48
(36-75V input), BWR-5/6-3.3/7-D24 (18-36V
input) and BWR-5/6-3.3/7-D12 (10-18V input)
are fully isolated DC/DC converters capable of
delivering any combination of 5V and 3.3V load-
ing up to a combined total of 33 Watts of output
power.
Housed in a standard 2" x 2" x 0.45" metal
package coated with electrically non-conductive
nish, these converters utilize a shared control-
loop system to assure load regulation of ±1% for
3.3V output and ±1.5% for 5V output. All models
include input Pi fi ltering, input overvoltage and
undervoltage shutdown circuitry, output overvolt-
age protection, output short-circuit and current
limiting protection, and thermal shutdown.
Each design also provides trim capability and
on/off control function. Fully synchronous output
rectifi cation renders high effi ciency and no-load
operation.
BWR power sharing modules offer low ripple
and noise performance, high effi ciency (88%),
1500Vdc of isolation voltage, and are fully
specifi ed for –40 to +100°C operation. These
devices meet IEC950, UL1950 and EN6950 safety
standards, including BASIC insulation require-
ments for “D48” models. CB reports are available
on request. “D48” models are CE marked (meet
LVD requirements).
Typical units
Typical topology is shown.
PRODUCT OVERVIEW

Summary of content (12 pages)