Service manual
When the air conditioner is in cooling and dry mode and 23 st 16 , during the 3 hours after sleep
mode 3 start up, the set temperature will increase by 1 every hour .The unit will continue operating
at 3 above the set temperature.
When 24 st 27 , during the 2 hours after sleep mode 3 start up, the set temperature will increase
by 1 every hour .The unit will continue operating at 2 above the set temperature.
When 28 st 31 ,the unit will operate at the set temperature all along.
When the air conditioner is in heat mode and18 st 16 , the unit will operate at the set temperature
all along.
Sleep mode 3
CONTROL SPECIFICATION
When 19 st 25 , during the 2 hours after sleep mode 3 start up ,the set temperature will decrease
by 1 every hour. The unit will continue operating at 2 below the set temperature.
When 26 st 31 ,during the 3 hours after sleep mode 3start up, the set temperature will decrease
by 1 every hour. The unit will continue operating at 3 below the set temperature.
22
INOIZER function(only applied to inoizer series)
Press inoizer button to start or stop inoizer function when the air conditioner is on or set timer.
The LED of the remote controller displays “ ” while it is initiated and extinguishes while it stops.
This function can only be stopped by pressing inoizer button or turning off the air conditioner.
PLASMA function (only applied to plasma series)
When the air conditioner is on, press CLEAN/PLASMA button to start or stop plasma function.
The LED of the remote controller displays “ ” while it is initiated and extinguishes while it stops.