CLEANINGTHE AIR OUTLET ANDTHE PANEL
CAUTIONS
Use a dry and soft cloth to wipe it.
Pure water or mild detergent may be used if it is
very dirty.
Do not use benzene, thinner, polishing power, or
similar solvents for cleaning. These may cause the
surface to crack or deform.
To avoid the risk of electrical shock or fire, do not let
water fall into the indoor unit.
Never wipe the air flow louver violently.
An air conditioner without air filter can not expel the
dust out of the room, which would cause
malfunctions by accumulation.
1.Injures may happen by improper operations
because of the sharp blade of some plates and the
freezer.
2.Check the air outlet and the air inlet of the outdoor
unit regularly to ensure that they are not choked by
filth or soot.
3.The coil and other parts of the outdoor unit should
also be checked regularly. Please contact with your
local dealer.
7. MAINTENANCE OFTHE OUTDOOR
UNIT
8. IF YOU DO NOT PLAN TO USE THE
UNIT FOR A LONGTIME
Operate the fan for about half a day to dry the inside
of the unit. Turn off the unit with the ON/OFF button
on the remote controller,then disconnect the power.
When the power switch is connected, some energy
will be consumed, even if the unit is not in operation.
So please disconnect the power to save energy. A
degree of filth will be accumulated due to certain
performance after several seasons of operation. So
special maintenance is advised. Take out of the
batteries from the remote controller.
Check the air outlets or inlets of the indoor/ outdoor
unit are not blocked. Check the grounding wire is not
broken off and is connected well.
The air filter and the front panel must be fixed to the
original position after having been cleaned.
To protect the air conditioner, power should be
provided 12 hours before operation. Then the
OPERATION lamp on the control box of the indoor
unit will flash once a second.
NOTE
RESTART AFTER A LONGTIME
1. Check before operation
2. Restore the air filter and the front panel
3. Connect the main power switch
MIDEA AIR-CONDITIONER AUXILIARY
HEATING EQUIPMENT
In winter, due to the difference of the area and
building construction, please purchase the indoor
unit with auxiliary heating to enlarge the heating
capacity. When turning to the heat mode the air-
conditioner with auxiliary heating will run at the set
temp.It's no need to install auxiliary heating
equipments on site for 4-way cassette type and
duct/ceiling type (with auxiliary heating)
!
EN
Owner's manual
Collision Mode
MALFUNCTION & PROTECTION
Collision Mode
Room temperature sensor checking
EEPROM
Water-level alarm malfunction
Outdoor malfunction
Pipe temperature sensor checking
Pipe temperature sensor checking
Avoid cold fan & defrost
Be closed by the remote control function
1
2
3
4
5
6
7
8
9
10
LED 1 LED 2 LED 3 LED 4
DISPLAY
DIGITAL
EO
E1
E2
E3
E4
E7
EE
Ed
CP
Extinguish Flashing at 5HZ Flashing at 1HZ