Installation Guide

9261-8252 Issue 07
Description
Page 21
www.multitone.com
Close the Alignment Window.
Setup is complete.
6.2 SLAVE TRANSMITTER
Connect the Field Programmer to RPT500 and read from the transmitter. Select Slave from the Line
Sync pull-down menu.
Write to the transmitter.
Click the Alignment button.
Click the Start Monitoring Line Sync Level button.
Check that the Line Sync Line Level bar shows a level of 300 or more. Preferably the bar should be
green, but this may not always be possible. If the level is below 300, return to the Master transmitter
and increase its output a little.
Click Stop Monitoring Line Sync Level.
Close the Alignment Window.
Setup is complete.
Synchronisation can take up to about 30 seconds to complete.
It is possible to check the status of the transmitter.
Click on the Action menu.