4.6 FREQUENCY ADJUSTMENT
If changing the frequency, enter the new frequency in the frequency box. If necessary the reference
frequency can be changed to 10000Hz. The new frequency must be a multiple of 10000 or 12500Hz
and in the range 430.000 to 470.000MHz. Set Alarm Set Power to required level. Reselect any other
parameters which need to be changed, then click Write. The new parameters are now stored in the
transmitter.
Click Alignment: