User Manual
13 i-Page Installation & User Guide 9261-8879 Iss 2
Field software update
The software involves a boot loader which can accept new software.
Turn the power off, wait for 10 seconds whilst the green power lamp extinguishes, depress
the button then repower the unit maintaining the button press for a few seconds. Release the
button. The green power lamp will come on, but if the ethernet cable is connected, the
ethernet LEDs will remain off. The serial port will now be available for input of a new i-Page
software issue.
Use the LM programme software to upload a new image. Connect a null modem cable
between i-Page and the computer, browse to the i-Page binary firmware file, select and
press PROGRAM.
Do not interrupt whilst the programme is being loaded and has reset i-Page, as this may
cause an irrecoverable error.
To resume normal operation after the upload, the ethernet LEDs must be flashing. If the
ethernet is not in use, then it may be advisable to repower the unit.
Check that i-Page is operating correctly and that a paging message may be sent.