User Manual
10 i-Page Installation & User Guide 9261-8879 Iss 2
5.12 Backup and restore
The backup and restore options allow you to save system data and restore if and when
required. Always backup your system data when first setting up i-Page or when any changes
are made to the settings.
To backup system data;
DOWNLOAD
o When the “file download” screen opens select SAVE
o Give the file a name / date and save to the i-Page folder
You will need to create this folder., this should be on the local network
for safety
To restore backup system data
o BROWSE for the file to be restored and select
Select UPLOAD. Do not interrupt the upload!
5.13 Factory reset
Factory reset will clear all system data and restore all settings to default.
-Page will need to be reprogrammed, either by the re-entry of new data, or by
restoring the most recent backup file. If you select the factory reset option, you will be
presented with the following message:-
Factory Reset
Proceeding with this action will delete all devices from the database and return all
settings to factory values.
Take a backup first if there is any possibility that the existing data is required.
After the reset the i-Page unit will be available on 192.168.1.11.
Use Admin password after a factory reset and your computer will need to have the static IP
address changed to 192.168.11.1 (see section 5.1).
6.0 Engineering button
The unit has an inset small blue button which has two different functions as follows:
A) Field software upgrades (see section 10.0)
B) Identification of the unit’s IP address
The Engineering button accessible from the front of i-Page toggles between normal
operation and engineering mode when power to the unit is maintained
To activate, do not remove power, press the button in and release the button after a few
seconds.
i-Page may now be accessed from its default IP address of 192.168.1.11,allowing access
when you don’t know the unit’s IP address.
The Administration password is also temporarily set to ”Admin”.