User Manual
4 i-Page Installation & User Guide 9261-8879 Iss 2
Once the bracket is attached to the wall, fit the power supply to the bracket by feeding the
DC output lead through the square hole in the bracket, from the inside. With the power
supply sitting centrally between the two lugs of the bracket, insert the mains connector into
the power supply through the oval hole, ensuring that it is fully pushed in.
This locks the power supply into the bracket.
Connect the power supply plug into the i-Page power
socket.
4.4 Network cable
Plug the network cable into a free network point and
the other end into the RJ45 network cable connector.
4.5 Aerial fitting
i-Page is supplied with a desktop aerial, with 4 metres of cable and connector. If an
alternative aerial is fitted, the impedance of the aerial should be 50 ohms.
Care must be taken during installation to keep the power supply away from excessive
RF fields.
Where the transmitter power is to be greater than 2.5W, the antenna must be sited a
minimum of 1.5 metres away from the i-Page housing and power supply.
In cases where a close-coupled antenna must be used, the transmitter power must be
reduced to a maximum of 2.5W and care must be taken to position the antenna at least 0.5
metres from the power supply unit.
Any equipment and antenna that is installed within an area normally populated whilst
it is in use, must be located in a position where people may not approach, or be
located within 1 metre of the radiating antenna, for periods in excess of 5 mins in any
1 hour. This distance is calculated to include an additional safety margin for the
product.
Note: You, (the user), are responsible for obtaining a license to operate your paging system
from Ofcom (UK), or your local radio/spectrum licensing agency.
http://licensing.ofcom.org.uk/binaries/spectrum/business-radio/forms/OfW432.pdf
5. i-Page setup
When i-Page has been assembled according to points 4.1 to 4.5 and the
ethernet cable from i-Page is connected to a network point, you are ready to
programme your system from your computer.
Note: Default IP address is 192.168.1.11 and network mask of 255.255.0.0
i-Page only supports a static / fixed IP address
A network address will need to be allocated by your MIS or IT manager