System Manual

EkoTek System Installation and Configuration Manual
9261-8173 issue: 8 Page 83
© 2012 Multitone Electronics Plc
Logging protocol format
Field no 1 2 3 4 5 6 7 8 9 10
Name Log
type
Message
type
Reason
code
Primary hardware
Primary serial no
Secondary hardware
Secondary serial no
Primary
name
Secondary
name
Message
Type Numeric Text
1
No response
required
2
Delivery
report
required
3
User
response
required
4
Delivery
report & user
response
required
1 Message
5
Externally
generated
message
2 Delivery
report
NA
1 Accept
4 (PG)
Paging
3 Message
response
2 Reject
Individually
addressed
destination
pager/
responding
pager
or
0,0 for
broadcast
or
0,pager
group
number for
pager group
NA NA
Blank for
broadcast,
or
pager group
name,
or
individual
pager name
NA
Message
text /
delivery
report /
user
response
3. Log examples
Key: Green: all SysLog messages; yellow: numeric output selected; blue: Text output
selected.
PS: Call fob raising manual alarm at reception repeater.
Note: The numbers in columns 4 to 7 are example serial number data. These will be
repeated throughout, but are omitted for clarity.
PS: Pager accepting (manual) alarm raised by call fob.
1 1 3 01
0
10000
39
030 00450
96
Call fob 1 Reception Assist