System Manual

EkoTek System Installation and Configuration Manual
9261-8173 issue: 8 Page 74
© 2012 Multitone Electronics Plc
Synchronisation
In a non-SER EkoTek system then the hub provides synchronisation clock to all the
radio elements in the system. When SERs are added then one of the SERs will
become the system synchronisation MASTER and the remaining SERs will be set as
Slaves. There can only be one Master on any system.
Select synchronisation on one SER only to be the Master and all others will be slave.
For the Master SER
the Master IP address can either be set to its own address
(10.1.101.154 in example) or (0.0.0.0).
For the Slave SERs
the Master IP address must be set to the Master IP,
(10.1.101.54 in example).
Note:
1. The timing port is set to 6114 by default this normally works for most systems but
you need to confirm with customer’s IT department to make sure this port is not
used in their network.
2. The radio must be switched off at the hub when using SERs to provide
synchronisation for system.
Note: radio
unchecked