System Manual

EkoTek System Installation and Configuration Manual
9261-8173 issue: 8 Page 70
© 2012 Multitone Electronics Plc
If a valid configuration has been uploaded to the hub, the following text is
displayed: ‘Use archive settings (will cause a hub reset and erase current
settings)’. The archived settings will not be applied until the hub is reset.
Click the reset button to change the hub configuration to the archived settings.
The process will take a few minutes, and is indicated by the normal separator in
the time field on the hub LCD screen being replaced by a flashing exclamation
mark. At this stage, trying to navigate within the EkoTek web pages can
interrupt the reset irreversibly. To avoid having to begin the upload process
again from the start, ensure that you monitor the hub LCD screen: when the
normal time separator returns, the process has completed. At this point the
web browser can be redirected to the new IP address of the hub.
13. Final checks
Connect a PC/Laptop to the hub via the customer’s Ethernet LAN connection.
Open the device status in the maintenance menu.
Check that all the repeaters are seen by the hub. If a repeater is not seen it may:
Be out of reach of a parent
Be faulty
Have a flat or disconnected battery
Investigate the cause using a survey pager. In cases where it is too far from the
nearest repeater to get a viable link a repeater may be needed to infill and complete
the mesh.
Click the details for each repeater and check the strength and quality of the link. If
the link looks marginal, remove the parent of that repeater from the network and see
if it will change to a different parent with a better link.
Seeing all repeaters may take some time with a large system.