System Manual

EkoTek System Installation and Configuration Manual
9261-8173 issue: 8 Page 66
© 2012 Multitone Electronics Plc
The following can be entered in the editing screen:
User group
Select the user group(s) always routed by this rule.
Zone
Select the zone(s) routed by this rule.
Time of day
Select the day and/or night settings of the shift mode.
Escalation
The escalation level of the alarm. ‘R’=raised, ‘N’=normal
Pager group
Select the target pager group.
EkoTek pagers only
When a rule has the ‘EkoTek pagers only’ option selected, messages using this
rule will not be sent to an external system. Rules with this option set are shown
as a shaded row in the alert mapping table, otherwise they are shown in white.
If ‘EkoTek pagers only’ is checked, a specified alarm event can be routed to
multiple pager groups, i.e. duplicate rules may be created allowing multiple
pager groups to be sent a message. In this mode external pagers will not be
contacted, so there is no conflict checking across alert maps.
Remove
Click the ‘Remove’ button to remove that rule from the table.
Add
Click the ‘Add’ button to enter a brand new rule; note that this option will only
appear if there are currently fewer than 32 rules.