System Manual

EkoTek System Installation and Configuration Manual
9261-8173 issue: 8 Page 63
© 2012 Multitone Electronics Plc
Tip-over trigger period
Length of time a device must be moved away from upright, until the user
warning buzzer sounds (seconds).
User alert period
Length of time that the buzzer sounds on the device, without it being returned
to the upright position and the cancel button pressed, before the alarm is raised
(seconds).
Snatch cord
For pagers fitted with a snatch cord (later models only).
Snatch cord enabled
When enabled, the user will raise an alarm whenever the snatch cord on a
pager fitted with this device is removed. The alarm will be automatically
cleared when the snatch cord is reattached.
Note: For earlier pager models without the snatch cord option, or where the
blanking plug is used instead of the snatch cord, this feature should always be
disabled.
Alert text
Modifiable text appears in the message sent to pagers when this alarm is
activated. Default text is ‘Snatched’.
Location alarm enabled
Enable the location-based alarm. This is raised if the unit is moved to an area
covered by repeaters assigned to an unauthorised zone. Check the box to
enable this feature. Enter the text to be displayed when the alarm is triggered.
Location audible alert / vibrate alert
The mobile device beeper and vibrate functions can be enabled or disabled
when the alarm is raised, allowing either covert or normal alarm operation.
Check boxes to enable alert.
Report in zones
To select those zones where the alarm is to be raised, check the box
associated with that zone. If the pager or call fob enters an unauthorised
(checked) zone the location alarm will be raised. The location alarm will be
cancelled automatically if the pager or call fob re-enters an authorised
(unchecked) zone.
Alarm clearance alert text
Modifiable text appears in the message sent to pagers when any alarm for this
device is cleared. The default text is ‘Cleared’.
Alarm escalation period
If an active alarm is not cleared within this period of time (minutes), then the
device resends the alarm with an alternate escalation level.
After selecting the above parameters, click ‘Submit’ to enter the changes.