System Manual

EkoTek System Installation and Configuration Manual
9261-8173 issue: 8 Page 22
© 2012 Multitone Electronics Plc
Installation
1. Preparation
Prerequisites
Prior to installation, the following items are needed:
Site plans with position of the hub and all the repeaters clearly marked
An AC mains socket outlet for the hub
An Ethernet connection to the customer LAN for the hub
A working telephone line and AC mains socket for the PPP connection
(if required)
A line for external ESPA or TAP system connection (if required)
Identify which PC is to be used for admin access and log file downloads
If installing SERs they will need an AC mains socket outlet plus
connection to the customer’s LAN
Tools recommended
Pozidriv screwdriver
Screwdriver with 2.5mm blade
Stepladder
Cordless drill
5mm masonry bit
6mm masonry bit
Metric rule
Laptop with Ethernet port
Ethernet patch cable
Call fob and pager from customer system
Survey pager
Equipment required
EkoTek hub with AC power supply unit
If modem access to a telephone link is required then use current
recommended modem with AC supply unit and a RS232 (proprietary)
connecting lead. See Appendix 3: RS232 cable pin-outs for connecting
the modem to the hub
EkoTek repeaters: quantity as required by survey. It is also suggested
that spare repeater/s are supplied, in case there is a need for infill that
was not detected on the survey (Ethernet repeater/s as required)