Installation Instructions
Table Of Contents
- Approvals
- System Overview
- Network Design and Survey
- Installation
- Pre-requisites
- Installing the Hub
- Repeaters
- PPP Modem
- The Browser Interface
- Accessing the HUB with the browser interface
- Connect the Hub to the PC using Windows XP
- Using the Web Browser to Access the EkoTek Hub
- Main menus
- Maintenance Menus
- Configuration menus
- Final Checks
- Appendices
- Related Documentation and Revision History
EkoTek System Installation and Configuration Manual Browser Interface
Hub Details
The device mode entry page hardware type is followed by the modifiable device mode
name (defaults 1->32).
Channel:
Select from the drop down menu (1 -> 16) to set the RF channel to be used by the Hub.
The default value of 15 should be sued where possible.
Location range:
Defines the range of the location signal from the Hub. The default value is ‘2’ which gives
an approximate range in indoor environments of 3m. A value of ‘1’ gives the shortest
range and ‘10’ the longest range. The range should not be set to high values in
deployments where location signal penetration through walls and floors is not desired.
Manual alarm enable:
Set the manual alarm and ways the device can raise manual alarms, i.e. via button
press(es).
Alert text:
Modify text to define the message sent to Pagers when the alarm is activated.
Defaults to ‘Assist’.
Opera t ion :
Define how many button presses are required to trigger the manual alarm (one or
two) selected by drop-down menu. Select either ‘Single click’ or ‘Double click’.
Alarm audible alert:
Define whether device buzzer sounds when manual alarm is raised.
Deadman alarm enable:
Enable the deadman automatic alarm. This is raised if no input is received from the User
when prompted by the device.
Alert text:
Modify text to define the message sent to Pagers when this alarm is activated.
Defaults to ‘No response’.
Timer interval:
Sets the time between User input prompts (minutes).
User alert period:
Sets the time that the buzzer prompt sounds on the device without User input, before
the alarm is raised (seconds).
9261-8173 Issue 2
Page 39
© 2007 Multitone Electronics PLC