Installation Instructions

Table Of Contents
EkoTek System Installation and Configuration Manual Browser Interface
The stats are simple incrementing counters.
Device Status Repeaters
Repeater: Serial Number.
Name: Name given to device.
Hardware-Software: Revision number.
Last Report: Time and date stamp.
Battery Level: Shows battery level. An alarm is given when battery level drops to 20% and
a replace battery message initiated at 5%.
Upstream Link: Name and serial number of Repeater or Hub connected to.
Beacon loss count = missed parent beacons. This counts the number of times the
Repeater has lost contact with its parent, either through faulty parent or degradation of the
signal to the parent.
Parent sync loss = number of times that a loss of sync with parent has occurred.
Link quality = general quality of link to parent. Scale 1 to 100 where 100=best.
Link strength = RSSI of parent link. Scale 1 to 100 where 100=best.
Upstream traffic = count of packets sent to parent.
The stats are simple incrementing counters.
Device Status Fob and Pager
Pager/Fob: Serial Number.
Name: Name given to device.
9261-8173 Issue 2
Page 30
© 2007 Multitone Electronics PLC