EkoTek System Installation and Configuration Manual Browser Interface
Maintenance Menus
Device Status
Device Status
Each device in the mesh connects to the Hub via a parent device (repeater or directly to
the hub itself). Maintaining this connection is important. These stats relate to that
connection. Status reports are made every 4 hours.
Device Status Hub
Hub: Serial Number.
Name: Name given to device.
Hardware-Software: Revision number.
Last Report: Time and date stamp.
Battery Level: For Hub will always be 100.
Upstream Link: The name of the parent device to which the local device is connected by
the radio mesh (reported on the Hub as ‘Direct connection’).
Beacon loss count = this records beacons lost during start up/reset.
Parent sync loss = number of times that a loss of sync has occurred.
Link quality = general quality of link to parent, Scale 1 to 100 where 100=best.
Link strength = RSSI of parent link, Scale 1 to 100 where 100=best.
Upstream traffic = count of packets sent to parent.