User`s guide
ADSL/VoIP Gateway User’s Guide Advanced DSL port attributes
106
Attribute Value Default
Activate Line Abort – deactivates the DSL link
None – signifies that this parameter has been read
Start – activates the DSL link
None
Host Control Disable – terminates any host/API interaction with the
DSP (for testing purposes)
Enable – enables host/API interaction with the DSP
Enable
Auto Start “True” - A Connection will be established at power up.
“False” - The modem will remain in Idle mode at power
up.
True
Failsafe True – a failsafe timer is activated when a startup
request is made. Once a connection has been
established, the failsafe timer is disabled
False – a failsafe timer is not activated when a startup
request is made
True
PSMode Possible Values:
“Inner” : Inner Pair Selected
“Outer” : Outer Pair Selected
This attribute is only present if Pair switching is enabled.
Inner
Whip Possible Values if compiled for Whip Serial:
Serial or Inactive
Possible Values if compiled for Whip TCP:
TCP or Inactive
Possible Values if compiled for Whip Serial/TCP:
Serial, TCP or Inactive
Inactive
Whip Active Indicated state of whip. Possible values are Inactive,
SerialActive and TCPActive
Inactive
Action An action given when ActivateLine is set to Start.
Possible values are Startup, SpectrumReverb,
SpectrumMedely or SpectrumPilot
Startup
Standard
Indicates the preferred standard compliance. Multimode
indicates that the device automatically detects the other
end as one of the supported standards.
Multimode
Utopia Interface Level1 – Utopia Level 1 internal framing is used with the
DSP
Level2 – Utopia Level 2 internal framing is used with the
DSP
Level1
EC FDM Mode EC – enables Echo Cancellation. This setting is
necessary if your device is connected to a high speed
CO.
FDM – enables Frequency Division Multiplexing
EC
Max Bits Per Bin The maximum number of bits per bin. This can be any
value between 1 and 15
15
Tx Start Bin A value that indicates the lowest bin number allowed for
transmit signal
6
Tx End Bin A value that indicates the highest bin number allowed for
transmit signal
31
Rx Start Bin A value that indicates the lowest bin number allowed for
receive signal
6
Rx End Bin A value that indicates the highest bin number allowed for
receive signal
255