ZDX Series Modem Racks Owner's Manual
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Owner’s Manual 82040205 Revision F ZDX Series Modem Racks This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright© 1998, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc.
Contents Chapter 1 - Introduction and Description Introduction ................................................................................ 8 Description ................................................................................. 8 Technical Specifications ..................................................... 10 Chapter 2 - Installation Power-Up Preliminaries ........................................................... 12 Safety Warnings ............................................................
vi
ZDX Series Modem Racks Chapter 1 - Introduction and Description
ZDX Series Modem Racks Owner's Manual Introduction Welcome to the world of data communications. You have one of the finest modem racks made today. This owner's manual provides information that will enable you to install and operate MultiModemZDX fax modems or other communications devices in your ZDXModemRack. This manual covers rack description, technical specifications, power supply, modem installation procedures, RS232C and phone line connections, and powering-up mode.
Chapter 1 - Introduction and Description The rack is equipped with a redundant, universal input 90-240v AC, 50/60 Hz power supply module. The rack, which measures 19 inches wide by 5-1/4 inches high, can be mounted in the same cabinet as your computer, or in a separate cabinet. Modem installation is accomplished by simply opening the rack door and sliding in the modems. RS232C cables and phone cords are connected to the modem's connectors at the back of the rack.
ZDX Series Modem Racks Owner's Manual Technical Specifications Rack Capacity: Up to 12 compact communication devices Connectors: IEC 320 Input Power Connector Dimensions: 19" wide x 5-1/4" high x 7-3/4" deep 48.26cm wide x 13.28cm high x 19.6cm deep Weights: Rack with power supply: 8 lbs (3.6 kg) Rack with power supply and 12 modems: 14.5 lbs (6.6 kg) Power Supply Input: Output: 90 to 240 Volts AC, 2.0 Amps 2-Amp Slo-Blo fuse +9 volts DC, regulated 4.
ZDX Series Modem Racks Chapter 2 - Installation
ZDX Series Modem Racks Owner's Manual Power-Up Preliminaries MultiModemZDX modems are shipped with Command mode enabled and the DTR signal controlled by the interface. It is generally assumed that rackmount modems are used in a central site computer environment (i.e., connected to a mini or mainframe computer) to automatically answer incoming calls from remote users. Unless you need to give the modem commands, you should disable Command mode.
Chapter 2 - Installation Installation Perform the following procedure to install the ZDX rack and install up to 12 modems (devices) in the rack. See Figure 2-1. 1. Unpack the rack and check all items against the shipping list to ensure that you have received the correct items. Rack Components A. B. C. Rack Power Cord Owner's Manual 2. Inspect the rack for visible shipping damage. If damage is observed, do not power-on the rack; contact Multi-Tech's Technical Support for advice (refer to Chapter 3). 3.
ZDX Series Modem Racks Owner's Manual SD RD CD 14 96 E4 DH TR EC FX SD RD CD 14 96 E4 DH SD TR RD EC CD FX 14 SD 96 RD E4 CD DH 14 TR 96 EC E4 FX DH SD TR RD EC CD FX 14 SD 96 RD E4 CD DH 14 SD TR 96 RD EC E4 CD FX DH 14 SD TR 96 RD EC E4 CD FX DH 14 TR 96 EC E4 FX DH SD TR RD EC CD FX 14 SD 96 RD E4 CD DH 14 TR 96 EC E4 FX DH SD TR RD EC CD FX 14 96 E4 DH TR EC FX SD RD CD 14 96 E4 DH TR EC FX Figure 2-1.
Chapter 2 - Installation 9. Repeat steps 6 through 8 for the remaining modems (devices). 10. If necessary, refer to the modem (device) Owner's Manual for connecting the cables and telephone lines to the modems (devices). 11. When all the modems (devices) are connected to the computer and the telephone lines, plug the AC power cord supplied with the rack into the power cord connector on the back of the rack and to a live AC outlet.
ZDX Series Modem Racks Owner's Manual 16
ZDX Series Modem Racks Chapter 3 - Service, Warranty and Tech Support
ZDX Series Modem Racks Owner's Manual Introduction This chapter starts out with statements about your modem rack's 2-year warranty. The next section, Tech Support, should be read carefully if you have questions or problems with your rack. It includes the technical support telephone numbers, space for recording your product information, and an explanation of how to send in your modem rack should you require service.
Chapter 3 - Service, Warranty and Tech Support MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS. Tech Support Multi-Tech has an excellent staff of technical support personnel available to help you get the most out of your MultiTech product. If you have any questions about the operation of this unit, call 1-800-972-2439. Please fill out the modem rack information (below), and have it available when you call.
ZDX Series Modem Racks Owner's Manual Service If your tech support specialist decides that service is required, your rack can be sent (freight prepaid) to our factory. Return shipping charges will be paid by Multi-Tech Systems. Include the following with your rack: • a description of the problem. • return billing and return shipping addresses. • contact name and phone number. • check or purchase order number for payment if the rack is out of warranty.
Chapter 3 - Service, Warranty and Tech Support The Multi-Tech BBS For customers who do not have Internet access, Multi-Tech maintains a bulletin board system (BBS) that mirrors its FTP site. Information available from the BBS includes new product information, product upgrade files, and problem-solving tips. The phone number for the Multi-Tech BBS is (800) 392-2432 (USA and Canada) or (612) 785-3702 (international and local).
ZDX Series Modem Racks Owner's Manual 5. Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the recommended protocol). 6. If you select Zmodem, the transfer will begin automatically. If you select another protocol, you may have to initiate the transfer yourself. (In most datacomm programs, the PAGE DOWN key initiates the download.) 7. When the download is complete, press ENTER to return to the File Menu. 8. To exit the BBS, type G and press ENTER.
Chapter 3 - Service, Warranty and Tech Support About CompuServe In addition to the BBS, Multi-Tech provides support through CompuServe's Modem Vendor Forum (GO MODEMVEN). Refer to your CompuServe documentation for special operating procedures. About the Internet Multi-Tech is a commercial provider on the Internet. If you prefer to receive service via the internet, you can contact Tech Support via e-mail at the following address: http://www.multitech.com/_forms/email_tech_support.
ZDX Series Modem Racks Owner's Manual 24
ZDX Series Modem Racks Appendices
ZDX Series Modem Racks Owner's Manual Appendix A - Safety Requirements 1. No manual adjustments to the equipment are necessary for connection to mains power within rated voltage and frequency. 2. The power supply cord is intended to serve as the disconnect device. The socket-outlet must be installed near the equipment and be easily accessible. 3. To reduce the risk of shock, all openings should be covered during normal operation of the equipment. 4.
Appendix A - Safety Requirements Requisitos de seguridad 1. No son necesarios ajustes manuales del equipo para la conexión a la corriente de la red dentro del voltaje y frecuencia establecidas. 2. El conector de alimentación de energía sirve como dispositivo de desconexión. La toma de corriente se debe instalar cerca del equipo y tener un acceso sencillo. 3. Para reducir el riesgo de sacudida eléctrica, todas las aberturas deben estar cubiertas durante el manejo normal del equipo. 4.
ZDX Series Modem Racks Owner's Manual Mains Wiring Instructions (U.K.) When wiring the mains plug, the following instructions must be followed: • the core which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol , or coloured green and yellow. • the core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
Appendix A - Safety Requirements Requisitos de potencia C.A. 90-245 V, 50/60 Hz, 2.0 Amp DC 40-56V, 2.5A ATTENCION: Adviertase que los requisitos respecto a medidas de seguridad no quedan satisfechos a menos que este equipo eléctrico esté conectado a una toma de corriente mural conectada a tierra. Stromaufnahme AC 90-245V, 50/60 Hz, 2.0A DC 40-56V, 2.5A VORSICHT: Die Sicherheitsvorschriften sind nur erfüllt, wenn das Gerät an eine geerdete Wandsteckdose angeschlossen ist.