FXO Parameters. The parameters applicable to the FXO telephony interface type are shown in the figure
below and described in the table that follows.
FXO Interface: Parameter Definitions*
Field Name Values Description
Interface Type FXO Enables FXO functionality
FXO Options
FXO Ring
Count
1-99 Number of rings required before the TalkAnytime answers the
incoming call.
No Response
Timer
1 – 65535
(in seconds)
Length of time before call connection attempt is abandoned.
Multi-Tech Systems, Inc. TalkAnyTime User Guide 83