FXS Loop Start Parameters. The parameters applicable to FXS Loop Start are shown in the figure below
and described in the table that follows.
FXS Loop Start Interface: Parameter Definitions
Field Name Values Description
FXS (Loop
Start)
Y/N Enables FXS Loop Start interface type.
FXS Loop Start Interface: Parameter Definitions (cont’d)
Field Name Values Description
FXS Options fields
FXS Ring
Count , FXS
1-99
Maximum number of rings that the TalkAnytime unit will issue
before giving up the attempted call.
Current Loss Y/N
When enabled, the TalkAnytime will interrupt loop current in the
FXS circuit to initiate a disconnection. This tells the device
connected to the FXS port to hang up. The TalkAnytime cannot
drop the call; the FXS device must go on hook.
Generate
Current
Reversal
Y/N
When selected, this option implements Answer Supervision and
Disconnect Supervision to the FXO interface using current
reversal to indicate events. Applicable only when FXS and FXO
interfaces are connected back to back.