User guide

TalkAnytime User Guide Technical Configuration
91
For TalkAnytime units, supervision of CAS protocols is supported only forFXS Ground Start and FXS Loop Start.
The parameters described in the following table for FXS Ground Start also apply to FXS Loop Start.
T1 Parameter Definitions
Field Name Values Description
FXS Ground/Loop Start
Supervision Parameters
Answer Delay
(Enable)
Y/N When this option is selected, the FXS interface sends the
connection notice to the calling party only when the
Answer Delay Timer expires. The connection notice is
sent regardless of whether or not the called extension has
gone offhook.
Answer Delay
Timer
numeric
(in seconds)
When Answer Delay is enabled, this value determines
when the FXS interface sends the connection notice.