User guide

Mechanical Installation & Cabling TalkAnytime User Guide
54
ETHERNET COMMAND
DIGITAL VOICE
ETHERN ET COMMAND
10 BASET
RS232
DIGITA L VO ICE
TRUNK
COMMAND
MODEM
Telco POTS Line
Grounding Screw
Figure 3-6. TA-2410/3010 TalkAnytime Connections
for Remote Config Modem & GND
5. Ensure that the TalkAnytime unit is properly connected to earth ground.
This can be accomplished by connecting a grounding wire between the chassis grounding screw (see
Figure 3-7) and a connector securely connected to the ground (GND) of the building’s electrical system.
Ground Connection Details. Ensure that the unit is securely and permanently connected to an earth
ground (GND) with a ground wire of 18 gauge (18 AWG) or thicker. The ground wire needs to be
installed between the grounding screw on the TalkAnytime chassis and a permanent earth ground.
Whether the TalkAnytime unit is used in a rack or on a desktop, you must verify that the earth ground
connection is permanent and reliable. In order for the ground connection to be considered permanent,
the grounding wire must connect to the earth ground of the building's electrical wiring system and the
ground connection must use a screw terminal or other reliable means of fastening. The ground
connection must not be as easily disconnected as, for example, a power cord.
Product
Ground
Screw
Grounding connectors
must be secured
permanently to
product ground screw
and earth ground screw.
Earth Ground Screw:
Connected to
Permanent Earth Ground
of Building’s
Electrical System
Ground
Wire:
Size 18AWG
or thicker
Multi-Tech
Product
GND
Figure 3-7. Earth Ground Details