User guide

MultiVOIP Quick Start Guide
12
4. Change the jumper block position for any voice/fax
channel to be connected to an E&M trunk that is not a
Type 2 (the default position).
5. Slide the base all the way into the cabinet until it stops.
6. Turn the MultiVOIP 200 upside down and replace the
cabinet mounting screw that was removed in step 2.
7. If you are using a Magix 400 E&M Tie Card, connect the
ground pin to the chassis ground screw as shown.
6
3
1
4
5
2
1
2
3
4
5
6
7
8
Male Male
PIN NO.
PIN NO.
MVP 200
Connection
Magix 400 E&M 4
Wire Tire Card
M MOUTH CONTROL
E EAR CONTROL
T1 TIP 1 RECEIVE
R RING TRANSMIT
T TIP TRANSMIT
R1 RING 1 RECEIVE
CHASSIS GROUND SCREW
UNUSED
M INPUT
E OUTPUT
T1 4-WIRE OUTPUT
R 4-WIRE INPUT, 2-WIRE
T 4-WIRE INPUT, 2-WIRE
R1 4-WIRE OUTPUT
SG (SIGNAL GND) OUTPUT
SB (SIGNAL BATTERY OUTPUT
8. Return the MultiVOIP 200 to its upright position, then
perform the cabling procedure.