User guide
Chapter 4—Configuring your VOIP
Multi-Tech Systems, Inc. 35
FXO Parameters
The parameters applicable to the FXO telephony interface type are shown in the figure below and described in
the table that follows.
FXO parameters
Field Name
Values
Description
Interface Type
FXO
Enables FXO functionality
Dialing Options
Regeneration
Pulse, DTMF
Determines whether digits generated and sent out will be pulse tones or DTMF.
Inter Digit Timer
1 to 10
seconds
This is the length of time that the MultiVOIP will wait between digits. When the
time expires, the MultiVOIP will look in the phonebook for the number entered.
Default = 2.
Message Waiting
Indication
--
Not applicable to FXO interface
Inter Digit
Regeneration Time
50 to 20,000
milliseconds
The length of time between the outputting of DTMF digits.
Default = 100 ms.
FXO Options
FXO Ring Count
1-99
Number of rings required before the MultiVOIP answers the incoming call.